Please use this identifier to cite or link to this item: http://lib.kart.edu.ua/handle/123456789/143
Full metadata record
DC FieldValueLanguage
dc.contributor.authorНерубацький, Володимир Павлович-
dc.contributor.authorПлахтій, Олександр Андрійович-
dc.contributor.authorГладка, Ангеліна Валеріївна-
dc.contributor.authorNerubatskyi, Volodymyr Pavlovych-
dc.contributor.authorPlakhtiy, Alexandr Andreevich-
dc.contributor.authorGladka, Angelina Valeriivna-
dc.date.accessioned2018-09-17T11:16:25Z-
dc.date.available2018-09-17T11:16:25Z-
dc.date.issued2018-
dc.identifier.citationНерубацький, В. П. Покращення електромагнітної сумісності тягового електропривода змінного струму шляхом застосування 4QS-випрямлячів / В. П. Нерубацький, О. А. Плахтій, А. В. Гладка // Збірник наукових праць Українського державного університету залізничного транспорту. - 2018. - Випуск 178. - С. 21-28.uk_UA
dc.identifier.issn1994-7852 (рrint); 2413-3795 (оnline)-
dc.identifier.urihttp://lib.kart.edu.ua/handle/123456789/143-
dc.description.abstractUA: У статті наведено систему керування вхідного 4Q-випрямляча, що реалізує коефіцієнт потужності тягового електропривода в режимах тяги та рекуперації близький до одиниці. Корекція коефіцієнта потужності реалізується як у режимі активного випрямляча, так і в режимі рекуперації. Виконано дослідження процесів в активному випрямлячі у програмному пакеті Matlab та виконано аналіз якості енергії. Запропоновано систему керування, яка реалізує режим рекуперації з високими енергетичними показниками.uk_UA
dc.description.abstractEN: One of promising areas of energy efficiency in railway transport is application of fourquadrant AC/DC converter with high power factor on the traction substations. The thyristor and diode three-phase rectifiers, which used on the AC/DC traction substations, have a number of drawbacks. In some cases, they do not provide the ability to recover energy, but also they are powerful source of current harmonic for general industrial electric grid. The presence of higher harmonics in power grid has the following negative consequences: distortion of the supply voltage; pickup in telecommunication and control circuits; heating and additional losses in transformers and electrical machines, which are powered from the power supply system; reducing the efficiency of the power supply system and technical devices. There are various topologies of active rectifier circuits for correction of power factor. However, it is worth noting that not all topologies of active rectifiers allow to implement bidirectional energy transfer. Neither VIAA rectifier circuit nor single-circuit three-phase rectifiers do not realize recovery. An optimal circuit for the recovery is the circuit of an active three-phase booster rectifier. The circuit allows to control the output voltage in the active rectifier mode, as well as the power factor close to one, both in the active rectification mode and in the recuperation mode. There are various control systems for active rectifier with correction of power factor. The most promising control systems are: hysteresis control system, vector control system and direct power control system. A significant advantage of a hysteresis control system is its relative simplicity of implementation, high reliability, high realized power factor.-
dc.publisherУкраїнський державний університет залізничного транспортуuk_UA
dc.subjectрекупераціяuk_UA
dc.subjectактивний підвищувальний випрямлячuk_UA
dc.subjectкорекція коефіцієнта потужностіuk_UA
dc.subjectfour-quadrant power conversionuk_UA
dc.subjectthree-phase active boost rectifieruk_UA
dc.subjectpower factor correctionuk_UA
dc.titleПокращення електромагнітної сумісності тягового електропривода змінного струму шляхом застосування 4QS-випрямлячівuk_UA
dc.title.alternativeEmc improvment research of three-phase active rectifiers with power factor correction in regenerative modeuk_UA
dc.typeArticleuk_UA
Appears in Collections:Випуск 178

Files in This Item:
File Description SizeFormat 
Nerubatskyi.pdf379.09 kBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.