Please use this identifier to cite or link to this item: http://lib.kart.edu.ua/handle/123456789/22132
Full metadata record
DC FieldValueLanguage
dc.contributor.authorРедько, Андрій Олександрович-
dc.contributor.authorРедько, Олександр Федорович-
dc.contributor.authorКаграманян, Артур Олександрович-
dc.contributor.authorБатюта, Максим Миколайович-
dc.contributor.authorКраснопольський, Денис Ігорович-
dc.contributor.authorRedko, Andriy-
dc.contributor.authorRedko, Oleksandr-
dc.contributor.authorKahramanyan, Artur-
dc.contributor.authorBatyuta, Maksym-
dc.contributor.authorKrasnopolsky, Denis-
dc.date.accessioned2024-04-19T09:08:41Z-
dc.date.available2024-04-19T09:08:41Z-
dc.date.issued2024-
dc.identifier.citationПрогнозування температурного режиму підземного колектора геотермальної циркуляційної системи теплопостачання / А. О. Редько, О. Ф. Редько, А. О. Каграманян, М. М. Батюта, Д. І. Краснопольський // Збірник наукових праць Українського державного університету залізничного транспорту. – 2024. – Вип. 207. – С. 14-23.uk_UA
dc.identifier.issn1994-7852 (print); 2413-3795 (online)-
dc.identifier.urihttp://lib.kart.edu.ua/handle/123456789/22132-
dc.description.abstractUA: Наведено результати чисельного дослідження температурного режиму пласта геотермального родовища. Розроблено математичну модель процесу теплообміну геотермальної рідини та гірської породи. Модель руху геотермальної рідини складає систему рівнянь нерозривності, кількості руху та енергії. Охолодження пласта визначається положенням фронту охолодження, який визначається ізотермою з температурою 288 К. Рішення одержано методом комп'ютерного моделювання. Показано значний вплив дебіту свердловин. При дебіті 10 м3 /год у період експлуатації 7500 год прогнозується зниження температури геотермальної рідини від 347 до 338 K, зі збільшенням дебіту до 100 м3 /год можливе зниження температури від 347 до 325 K.uk_UA
dc.description.abstractEN: The results of a numerical study of the temperature regime of a geothermal field formation are presented. A mathematical model of the heat exchange process between geothermal fluid and rock has been developed. The model of geothermal fluid movement consists of a system of continuity, momentum, and energy equations. At the beginning of computer modeling, the geometry, system parameters, as well as initial and boundary conditions are defined. Water injection technology maintains reservoir pressure and high flow rates, but leads to a decrease in temperature in the aquifer. Reducing the temperature of the geothermal fluid is a crucial issue for long-term operation, the prediction of which is possible with the help of computer modeling. The cooling of the formation is determined by the position of the cooling front, which is defined by an isotherm with a temperature of 288 K. The solution has been obtained by computer modeling. It has been shown that the displacement of the formation cooling front is determined by the thermophysical properties of the rock formations, filtration rate, physical properties of the geothermal fluid, and the temperature of the geothermal fluid supplied to the injection well. The relationship governing the displacement of the formation cooling front has been obtained. The cooling of the formation depends on the distance between the production and injection wells of geothermal fluid and the pressure drop in the formation. The significant influence of the flow rate of the wells has been shown. With a flow rate of 10 m 3 /h over an operating period of 7500 hours, the temperature of the geothermal fluid is predicted to decrease from 347 K to 338 K; with an increase in flow rate to 100 m 3 /h, a decrease in temperature from 347 K to 325 K is possible. It has been shown that the cooling of the formation mainly occurs in the horizontal plane. Comparison of obtained numerical data with known literature has been performed. Extending the operational lifespan is possible through the implementation of the periodic short-term operation-stop technology (a 10-year cycle, totaling 100 years). This technology allows for greater heat extraction compared to longer-term operation (a 50-year cycle, totaling 100 years). Additionally, increasing the distance between production and injection wells to 1000-1500 meters reduces cooling rates and prolongs the lifespan of the geothermal system. When forecasting the temperature regime of geothermal reservoirs, it is necessary to monitor and refine mathematical models with operational and well research data.-
dc.publisherУкраїнський державний університет залізничного транспортуuk_UA
dc.subjectтемпературний режимuk_UA
dc.subjectгеотермальне родовищеuk_UA
dc.subjectтеплообмінuk_UA
dc.subjectсвердловинаuk_UA
dc.subjectдебітuk_UA
dc.subjectпластuk_UA
dc.subjectматематична модельuk_UA
dc.subjectкомп'ютерне моделюванняuk_UA
dc.subjecttemperature regimeuk_UA
dc.subjectgeothermal fielduk_UA
dc.subjectheat exchangeuk_UA
dc.subjectwelluk_UA
dc.subjectflow rateuk_UA
dc.subjectreservoiruk_UA
dc.subjectmathematical modeluk_UA
dc.subjectcomputer modelinguk_UA
dc.titleПрогнозування температурного режиму підземного колектора геотермальної циркуляційної системи теплопостачанняuk_UA
dc.title.alternativePrediction of the temperature regime of an underground collector in a geothermal circulation-based heating systemuk_UA
dc.typeArticleuk_UA
Appears in Collections:Випуск 207

Files in This Item:
File Description SizeFormat 
Redko.pdf1.15 MBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.