Please use this identifier to cite or link to this item:
http://lib.kart.edu.ua/handle/123456789/363
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Фалендиш, Анатолій Петрович | - |
dc.contributor.author | Клецька, Ольга Віталіївна | - |
dc.contributor.author | Бітюра, Євген Анатолійович | - |
dc.contributor.author | Falendysh, Anatoliy | - |
dc.contributor.author | Kletska, Olga | - |
dc.contributor.author | Bityura, Evgeniy | - |
dc.date.accessioned | 2018-10-22T10:48:27Z | - |
dc.date.available | 2018-10-22T10:48:27Z | - |
dc.date.issued | 2016 | - |
dc.identifier.citation | Фалендиш А. П. Модель розрахунку твердопаливного котла невеликої потужності / А. П. Фалендиш, О. В. Клецька, Є. А. Бітюра // Збірник наукових праць Українського державного університету залізничного транспорту. - 2016. - Випуск 166. - С.185-190. | uk_UA |
dc.identifier.issn | 1994-7852 (print); 2413-3795 (online) | - |
dc.identifier.uri | http://lib.kart.edu.ua/handle/123456789/363 | - |
dc.description.abstract | UA: У даній статті зроблений аналіз різних видів розрахунків котлів для опалення приміщень, який показав, що в основному розрахунки котлів виконують Нормативним методом. В роботі доведена неефективність використання даного методу для розрахунку котлів невеликої потужності, його можна використовувати лише для котлів великої потужності. Аналіз відомої літератури показав, що методам розрахунку котлів невеликої потужності уваги приділяється недостатньо. Таким чином, була запропонована модель розрахунку твердопаливного котла потужністю до 100 кВт, яка базується на Нормативному методі розрахунку, але має свої особливості. | uk_UA |
dc.description.abstract | EN: In this paper, an analysis of various types of calculations boilers for space heating, which showed that most settlements boilers perform standard method. The work proved inefficient use of the method for calculating boiler low power, it can only be used for high power boilers. Analysis of the known literature showed that the method of calculation boilers emphasis on low power enough. High urgency of using solid fuel boilers for heating small spaces and methods of calculation clearly evidenced by the large number of articles and scientific papers presented in the technical periodicals. Verification calculation can be done one of the following methods: normative method, pryblyzhen serial, parallel calculations and counter calculation boiler. But all these methods are used to calculate the high power boilers. Therefore, the development model calculation of solid fuel boilers is a low-power objective and timely manner aktualnoyu.Takym proposed a model calculation of solid fuel boilers up to 100 kW, which is based on the standard method of calculation, but has its own peculiarities. | - |
dc.publisher | Український державний університет залізничного транспорту | uk_UA |
dc.subject | твердопаливний котел | uk_UA |
dc.subject | перевірочний | uk_UA |
dc.subject | аеродинамічний | uk_UA |
dc.subject | метод розрахунку | uk_UA |
dc.subject | топка | uk_UA |
dc.subject | solid fuel boiler | uk_UA |
dc.subject | verification | uk_UA |
dc.subject | aerodynamic | uk_UA |
dc.subject | the method of calculation | uk_UA |
dc.subject | furnace | uk_UA |
dc.title | Модель розрахунку твердопаливного котла невеликої потужності | uk_UA |
dc.title.alternative | Model calculation solid fuel boilers low power | uk_UA |
dc.type | Article | uk_UA |
Appears in Collections: | Випуск 166 |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
Falendysh.pdf | 152.38 kB | Adobe PDF | View/Open |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.