Please use this identifier to cite or link to this item:
http://lib.kart.edu.ua/handle/123456789/8990
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Нерубацький, Володимир Павлович | - |
dc.contributor.author | Плахтій, Олександр Андрійович | - |
dc.contributor.author | Кавун, Віталій Євгенович | - |
dc.contributor.author | Машура, Артем В’ячеславович | - |
dc.contributor.author | Гордієнко, Денис Анатолійович | - |
dc.contributor.author | Цибульник, Владислав Романович | - |
dc.contributor.author | Nerubatskyi, Volodymyr Pavlovych | - |
dc.contributor.author | Plakhtiy, Alexandr Andreevich | - |
dc.contributor.author | Kavun, Vitaliy Evgenyevich | - |
dc.contributor.author | Mashura, Artem Vyacheslavovych | - |
dc.contributor.author | Hordiienko, Denys Anatolievych | - |
dc.contributor.author | Tsybulnyk, Vladislav Romanovych | - |
dc.date.accessioned | 2022-04-29T12:57:26Z | - |
dc.date.available | 2022-04-29T12:57:26Z | - |
dc.date.issued | 2018 | - |
dc.identifier.citation | Нерубацький В. П. Аналіз показників енергоефективності автономних інверторів напруги з різними типами модуляції / В. П. Нерубацький, О. А. Плахтій, В. Є. Кавун, А. В. Машура, Д. А. Гордієнко, В. Р. Цибульник // Збірник наукових праць Українського державного університету залізничного транспорту. - 2018. - Вип. 180. - С. 106-120. | uk_UA |
dc.identifier.issn | 1994-7852 (print); 2413-3795 (online) | - |
dc.identifier.uri | http://lib.kart.edu.ua/handle/123456789/8990 | - |
dc.description.abstract | UA: У статті наведено аналіз енергетичних характеристик та показників електромагнітної сумісності автономних інверторів напруги з різними типами модуляції. Розглянуто режими однократної модуляції зі 120-, 150- і 180-градусним керуванням, одностороння та двостороння ШІМ, а також перемодуляція в ШІМ. Подано порівняльний аналіз реалізованих показників пульсації вхідного струму, синусоїдальності вихідного струму, значень статичних та динамічних втрат в силових ключах. Дані отримано шляхом імітаційного моделювання, а також розрахунку в спеціалізованій програмі MelcoSim від компанії Mitsubishi. Визначено, що режим перемодуляції дозволяє отримати найкращі показники якості вихідного струму інвертора. | uk_UA |
dc.description.abstract | EN: In the article an analysis of energy characteristics and indices of electromagnetic compatibility of autonomous inverters of voltage with different types of modulation is given. Modes of single modulation with 120-, 150- and 180-degree control, one-way and two-way pulse-width modulation, as well as re-modulation mode are considered. The comparative analysis of the implemented parameters of the incoming current pulsation, sinusoidality of the output current, and the values of static and dynamic losses in power switches is presented. The data is obtained through simulation simulation, as well as calculation in the specialized program of MelcoSim from the company Mitsubishi. The obtained analytical expressions allow to determine the values of the amplitudes of higher harmonics in the forms of the output voltage and the output current of the autonomous voltage inverter under different algorithms of single modulation. It is established that the classical diagrams of the output voltage of the autonomous inverter voltage at 120- and 180- degree control are valid only for the resistive load and in the case of an RL load will have a distorted form. The dependencies of the output current THD, the THD of the output voltage, as well as the amplitude of the first harmonic of the output voltage on the value of the modulation coefficient are established. With the growth of the re-modulation coefficient, the amplitude of the output voltage increases, but with this there is an increase in the content of higher harmonics with frequencies lower than the frequency of pulse-width modulation. From the considered modulation algorithms in the autonomous voltage inverter, the smallest losses in the keys and the highest output power causes the mode of 180-degree control, and the best quality of the output voltage and current causes the mode of 150-degree control. | - |
dc.publisher | Український державний університет залізничного транспорту | uk_UA |
dc.subject | алгоритм | uk_UA |
dc.subject | гармоніки | uk_UA |
dc.subject | енергоефективність | uk_UA |
dc.subject | інвертор напруги | uk_UA |
dc.subject | керування | uk_UA |
dc.subject | моделювання | uk_UA |
dc.subject | модуляція | uk_UA |
dc.subject | перетворювач | uk_UA |
dc.subject | algorithm | uk_UA |
dc.subject | harmonics | uk_UA |
dc.subject | energy efficiency | uk_UA |
dc.subject | voltage inverter | uk_UA |
dc.subject | control | uk_UA |
dc.subject | simulation | uk_UA |
dc.subject | modulation | uk_UA |
dc.subject | converter | uk_UA |
dc.title | Аналіз показників енергоефективності автономних інверторів напруги з різними типами модуляції | uk_UA |
dc.title.alternative | Analysis of indices of energy efficiency of autonomous voltage inverters with various modulation types | uk_UA |
dc.type | Article | uk_UA |
Appears in Collections: | Випуск 180 |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
Nerubatskyi.pdf | 428.66 kB | Adobe PDF | View/Open |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.