Please use this identifier to cite or link to this item: http://lib.kart.edu.ua/handle/123456789/89
Full metadata record
DC FieldValueLanguage
dc.contributor.authorХарламов, Павло Олександрович-
dc.contributor.authorФедоров, Артем Вікторович-
dc.contributor.authorХарламова, Олена Миколаївна-
dc.contributor.authorДзюба, Олена Анатоліївна-
dc.contributor.authorKharlamov, Pavlo-
dc.contributor.authorFedorov, Artem-
dc.contributor.authorKharlamova, Olena-
dc.contributor.authorDziuba, Olena-
dc.date.accessioned2018-07-11T08:51:05Z-
dc.date.available2018-07-11T08:51:05Z-
dc.date.issued2017-
dc.identifier.citationХарламов П. О. Перспектива розроблення системи електричної тяги постійного струму підвищеної напруги / П. О. Харламов, А. В. Федоров, О. М. Харламова, О. А. Дзюба // Збірник наукових праць Українського державного університету залізничного транспорту. - 2017. - Випуск 173. - С. 199-204.uk_UA
dc.identifier.issn1994-7852 (рrint); 2413-3795 (оnline)-
dc.identifier.urihttps://lib.kart.edu.ua/handle/123456789/89-
dc.description.abstractUA: Залізниці країн СНД здебільшого електрифіковані на постійному струмі при напрузі в контактній мережі 3 кВ. Однак така напруга не є оптимальною ані для обладнання електропостачання, ані для електрорухомого складу. Вона є компромісною та обумовлена вартістю втрат енергії в такій системі й вартістю її обладнання. Підвищення ж напруги в контактній мережі постійного струму в кілька разів дасть змогу суттєво поліпшити техніко-економічні показники системи тяги постійного струму. Нові можливості щодо цього відкриває застосування систем імпульсного перетворення енергії, що усувають безпосередній зв'язок між напругами контактної мережі й тягових двигунів.uk_UA
dc.description.abstractEN: The majority of CIS railways are electrified on DC with a voltage in the contact network of 3 kV. However, such a voltage is not optimal either for power supply devices or for electric rolling stock. It is a compromise solution, determined by the cost of energy losses in such a system and the cost of its devices. An increase in the voltage in the contact network of a direct current, for example, up to 6 or 12 kV or more, in order to reduce the energy losses in the system under the existing principles of regulating the operating conditions of the emitter. p.s. leads to a significant increase in the cost of electrical equipment and traction engines. It is characteristic that the noted shortcomings of the DC traction system of 3 kV are due to the fact that there is a direct electrical connection between the voltage of the contact network and the voltage of the traction electrical equipment. If this connection is eliminated and it is possible to regulate voltages on traction engines within wide limits, it will be possible to increase the voltage in the contact network several times to significantly improve the technical and economic performance of the DC traction system. New possibilities in this respect are opened by the use of pulsed energy conversion systems, which eliminate the direct connection between the voltages of the contact network and traction motor.-
dc.publisherУкраїнський державний університет залізничного транспортуuk_UA
dc.subjectелектрифікаціяuk_UA
dc.subjectтягаuk_UA
dc.subjectструмuk_UA
dc.subjectнапругаuk_UA
dc.subjectelectrificationuk_UA
dc.subjecttractionuk_UA
dc.subjectcurrentuk_UA
dc.subjectvoltageuk_UA
dc.titleПерспектива розроблення системи електричної тяги постійного струму підвищеної напругиuk_UA
dc.title.alternativeThe prospect of the development of the electric traction system of dc high voltageuk_UA
dc.typeArticleuk_UA
Appears in Collections:Випуск 173

Files in This Item:
File Description SizeFormat 
Kharlamov.pdf179.71 kBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.