Please use this identifier to cite or link to this item:
http://lib.kart.edu.ua/handle/123456789/17345
Title: | Исследование поверхностей отклика при оптимизации режима трехфазной системы электроснабжения |
Other Titles: | Research of surfaces of response during optimization of mode of three-phase system of power supply |
Authors: | Ягуп, Екатерина Валериевна |
Keywords: | поверхні відгуку лінії рівного рівня оптимізація симетруючі конденсатори реактивна потужність response surfaces lines of equal level optimization balanced condensers reactive power |
Issue Date: | 2012 |
Publisher: | Технологічний центр |
Citation: | Ягуп Е. В. Исследование поверхностей отклика при оптимизации режима трехфазной системы электроснабжения / Е. В. Ягуп // Восточно-Европейский журнал передовых технологий. - 2012. - Т. 6, № 8(60). - С. 56-59. |
Abstract: | UA: У пакеті MATLAB була складена візуальна модель системи електропостачання електрорухомого складу з нерівномірним активно-індуктивним навантаженням в кожній з трьох фаз. Для симетрування струмів і компенсації реактивній потужності в систему електропостачання були підключені симетруючі міжфазні конденсатори. При визначенні оптимальних значень ємкостей конденсаторів, що мінімізують значення реактивної потужності,були побудовані поверхні відгуку. EN: In an application package MATLAB was made visual model of the system of power supply of electic train with the uneven active-inductive loading in each of three phases. For currents symmetrization and reactive-power compensation balanced interphase condensers were included in the system of power supply. For determination of optimum values of condensers capacities at which spherical metric, namely, square root from the sum of squares of reactive-powers, arrived at the minimum value, response surfaces were built. Thus taking into account that circum-stance, that in MATLAB application is possible to build line of equal levels just for function of two variables, three diagrams were built. In each of diagrams one of three values of condensers was fixed, and was equal before found optimum value. As a result of construction of lines of equal level without implementation of optimization the geometrical place of values of balanced condensers at which reactive-power in the system of power supply reached minimum value. |
URI: | http://lib.kart.edu.ua/handle/123456789/17345 |
ISSN: | 1729-3774 (print); 1729-4061 (online) |
Appears in Collections: | 2012 |